Products

PUR Shielded Twisted-Pair Sensor Cable

Connection cable between sensors and control systems For data acquisition and transmission in industrial automation Suitable as connection lines for almost all monitoring equipment Can be used in most fields of signal acquisition, transmission and processing Suitable for indoor and outdoor environments Suitable for EMC-sensitive environments
Product Features
  • Complies with flame retardance standard IEC60332-1-2
  • Good chemical resistance
  • Allows small cable diameters
  • Core arrangement complies with EU standards
Technical Approvals
  • Complies with DIN VDE295 standard
  • Complies with IEC 60228 class 6 conductor standard
  • Meets EU core arrangement specifications
Cable Construction
  • Conductor: multi-strand, finely stranded copper conductor complying with DIN VDE295 and IEC 60228 class 6
  • Insulation: special PVC compound or PP material
  • Insulation colors: 3 cores (1-brown, 2-blue, 3-black); 4 cores (1-brown, 2-white, 3-blue, 4-black); 5 cores (1-brown, 2-white, 3-blue, 4-black, 5-grey); 8 cores (0-red, 1-white, 2-brown, 3-green, 4-yellow, 5-grey, 6-pink, 7-blue)
  • Jacket: special PVC compound or PUR material
  • Jacket colors: black RAL9005, grey RAL7001, orange RAL2003, etc.
Technical Parameters
Technical Parameter Details
Rated voltage U0/U 300/300V
Test voltage 1500V
Operating temperature range - fixed installation Standard PVC: -10℃/+80℃; cold-resistant and heat-resistant PVC: -40℃/+105℃; oil-resistant PUR: -40℃/+105℃
Operating temperature range - moving installation Standard PVC: -5℃/+80℃; cold-resistant and heat-resistant PVC: -15℃/+105℃; oil-resistant PUR: -20℃/+105℃
Motion performance - travel ≤20m
Motion performance - acceleration ≤10m/s²
Motion performance - speed Overhead 3m/s; sliding 2m/s
Motion performance - continuous return cycles 5 million cycles (radius ≥10D, 2m/s, 60 cycles/min)
Minimum bending radius - fixed installation 6× cable outer diameter
Minimum bending radius - moving installation (travel distance <10m) 7.5× cable outer diameter
Minimum bending radius - moving installation (travel distance ≥10m) 10× cable outer diameter

Delivery Standards

  • Custom production by specified length or cutting of existing products available (please specify the details in your order).
  • Custom production or cutting to specified lengths as required (please note the relevant requirements in detail in your order).
  • For special specifications, colors or other requirements, please contact our customer service for further discussion.