All-Dielectric Gel-Filled Tube Temperature Sensing Cable

All-Dielectric Gel-Filled Tube Temperature Sensing Cable
Application scenarios
  • Power system applications: temperature monitoring in cable trenches, cable interlayers, cable tunnels, etc.
  • Transportation infrastructure: temperature monitoring in tunnels such as expressways and subways.
  • Building fire protection scenarios: fire temperature monitoring in large buildings such as factories, halls and granaries.
  • Other scenarios: DTS temperature measurement in environments with strong electric and magnetic field interference, and general temperature measurement needs.
Product features
  • Fully all-dielectric structure, suitable for complex environments with strong electric and magnetic fields.
  • Protected by a high-strength PBT tube, with stable and reliable mechanical performance.
  • Low-loss design with excellent fiber transmission performance.
  • Flame-retardant outer sheath material with good electrical insulation performance.
  • High water resistance, no metallic components, simple and practical structure.
Color identification
  • (1) Fiber colors (corresponding to 1-12 fibers)
  • Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Purple, Pink, Light Blue
  • (2) Cable colors (corresponding to 1-12)
  • Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Purple, Pink, Light Blue
  • Note: The outer sheath of the standard all-dielectric gel-filled tube temperature sensing cable is blue by default.
Environmental certifications
  • Compliant with EU RoHS and REACH certification standards.
Structural dimensions
Item Unit Specification One-side thickness (mm)
Fiber mm 0.25±0.005 -
PBT gel-filled tube mm 2.00±0.10 0.45
Kevlar fibers mm 2.20±0.10 -
Cable outer sheath mm 4.00±0.20 0.90
Cable weight Kg/km 120 -
Fiber performance
  • (1) Geometric characteristics
Test item MM 50 MM 62.5
Mode field diameter (mm) 50±2.5 62.5±2.5
Cladding diameter (mm) 124.8±1.0 124.8±1.0
Cladding non-circularity (%) ≤1.0 ≤1.0
Core-cladding concentricity error (mm) ≤1.5 ≤1.5
Coating diameter (mm) 245±7 245±7
Outer coating-cladding concentricity error (mm) ≤12.0 ≤12.0
  • (2) Optical characteristics
Test item MM 50 MM 62.5
Zero-dispersion wavelength λ0 (nm) 1295-1320 1320-1365
Zero-dispersion slope S0 (ps/(nm².km)) ≤0.101 ≤0.097
Effective group index (850nm) 1.481 1.496
Effective group index (1300nm) 1.476 1.491
Typical attenuation (850nm) dB/km ≤3.0
Typical attenuation (1300nm) dB/km ≤1.0
Cable performance
Item Unit Multimode specification
Fiber count fiber 1~2
Cable outer diameter mm 4.00±0.20
Permissible tensile strength (long-term) N 500
Permissible tensile strength (short-term) N 800
Permissible crushing force (long-term) N/100mm 800
Permissible crushing force (short-term) N/100mm 1000
Permissible bending radius (dynamic) mm 80
Permissible bending radius (static) mm 40
Operating temperature (long-term) -20~85
Operating temperature (short-term 2 hours) -40~125
Cable net weight kg/km 120
Marking information
  • Standard marking: Manufacturer info + Optic Fiber CABLE + MM 50/125 4.0mm + Fiber count + Month/Year + XXXXm
  • Custom marking content available per customer requirements.
Cable drum length
  • Standard drum lengths: 500m, 1000m, 2000m
  • 10% over/under shipment allowed; settlement based on actual shipped length.

Related Products