For connection to DTS temperature measurement equipment; equipped with connectors that can be plugged directly into the equipment without the need for pigtail splicing
For temperature sensing environments such as tunnels, subways, bridges and dams, and for fire alarm systems
Features
High tensile and crush strength
Good environmental adaptability, tolerant of high and low temperature differences
Meets the national standard flame retardancy requirements for optical fiber cables
Soft, flexible and easy to splice, making it especially suitable for on-site cabling installation
The cable structure can be modified to meet customer requirements, further enhancing its special adaptability
Construction & Dimensions
Item
Unit
Specification
Single-Side Thickness
Optical fiber
mm
0.60±0.05 or 0.90±0.05
-
Spiral steel tape armor
mm
1.70±0.10
0.25
Kevlar fiber
mm
1.80±0.10
-
Metal braided mesh
mm
2.10±0.10
0.07
Cable outer jacket
mm
2.85±0.10
0.35
Cable weight
Kg/km
18
-
Fiber Performance (Geometrical Characteristics)
Test Item
MM 50
MM 62.5
Mode field diameter mm
50±2.5
62.5±2.5
Cladding diameter mm
124.8±1.0
124.8±1.0
Cladding non-circularity %
≤1.0
≤1.0
Core-cladding concentricity error mm
≤1.5
≤1.5
Coating diameter mm
245±7
245±7
Outer coating-cladding concentricity error mm
≤12.0
≤12.0
Optical Characteristics
Test Item
MM 50
MM 62.5
Zero dispersion wavelength λ0 nm
1295-1320
1320-1365
Zero dispersion slope S0 ps/(nm².km)
≤0.101
≤0.097
Effective group index
850nm
1300nm
850nm
1300nm
1.481
1.476
1.496
1.491
Cable Technical Parameters
Item
Unit
Multi-Mode (50)
Multi-Mode (62.5)
Core/modal diameter
mm
50.0±2.5mm
62.5±2.5mm
Cladding diameter
mm
125±1mm
125±1mm
Maximum attenuation
dB/km
3.5dB/km@850nm;1.5dB/km@1300nm
3.5dB/km@850nm;1.5dB/km@1300nm
Operating temperature
℃
-40℃~+85℃
-40℃~+85℃
Cable outer diameter
mm
2.85±0.10
2.85±0.10
Cable net weight
Kg/km
18
18
Allowable bending radius
mm
Dynamic 20D static 10D
Dynamic 20D static 10D
Allowable tensile load
N
Long-term 200 short-term 400
Long-term 200 short-term 400
Crush resistance
N/10cm
Long-term 3000 short-term 5000
Long-term 3000 short-term 5000
Color Identification
No.
1
2
3
4
5
6
7
8
9
10
11
12
Fiber color
Blue
Orange
Green
Brown
Grey
White
Red
Black
Yellow
Purple
Pink
Light blue
No.
1
2
3
4
5
6
7
8
9
10
11
12
Cable color
Blue
Orange
Green
Brown
Grey
White
Red
Black
Yellow
Purple
Pink
Light blue
Remarks
(1) The outer jacket of the temperature sensing armored cable is red; (2) Polyurethane (PU) material is available in black jacket only.